Address
304 North Cardinal
St. Dorchester Center, MA 02124

Work Hours
Monday to Friday: 7AM - 7PM
Weekend: 10AM - 5PM

CJMCU-219 INA219 I2C Interface Power Supply Monitoring Module

Original price was: ₹350.00.Current price is: ₹209.00.

  • CJMCU219 Programmable calibration register can be read in units of ampere direct current, and read the power in watts.
  • Up to 128 samples can be averaged to achieve filtering in noisy environments.
  • I2C interface has a timeout setting, not only to prevent bus lock but also to provide high-speed mode, to meet the communication requirements of up to 3.4 MHz.
  • All properties INA219 are software programmable to support.
  • A single power supply, the operating voltage of between +3.0 to + 5.5V.
SKU: RS1979 Categories: ,

CJMCU219 is a module with the I2C interface of zero drift and bi-directional current/power monitoring and control integrated circuit (IC). INA219 has the industry’s highest precision and the small size, not only can monitor the pressure drop on the shunt resistor, sensing shunt power supply voltage, at the same time also can calculate the power. This breakout board will solve all your power-monitoring problems. Instead of struggling with two multimeters, you can just use the handy INA219B chip on this breakout to measure both the high side voltage and DC current draw over I2C with 1% precision. The device adopts the SOT23 packaging, but for the server, notebook computer, power supply, battery management and digital electric vehicle and telecommunication equipment measuring flu provide a small low-cost solution. A precision amplifier measures the voltage across the 0.1, 1% sense resistor. Since the amplifier maximum input difference is ±320mV this means it can measure up to ±3.2 Amps. With the internal 12 bit ADC, the resolution at ±3.2A range is 0.8mA. With the internal gain set at the minimum of div8, the max current is ±400mA and the resolution is 0.1mA. Advanced hackers can remove the 0.1-ohm current sense resistor and replace it with their own to change the range (say a 0.01 ohm to measure up to 32 Amps with a resolution of 8mA). INA219-40 c to + 85 c temperature range and can realize the maximum error of 1% accuracy, a maximum offset of 100 μV. The advantage of the high precision of the product in combination with 12 resolution, can help clients as much as possible, reduce the pressure drop on the shunt resistor, which can minimize the power loss and power consumption, and save board space. The device epic of 26 bus voltage range of 0 V to + V.

CJMCU219 Specification:

  • Operating Voltage: 3 ~ 5.5V DC
  • Accuracy: ±0.5%
  • Operating Temperature Range: -40 to 85°C

CJMCU219 Features:

  • The programmable calibration register can be read in units of ampere direct current, and read the power in watts.
  • Up to 128 samples can be averaged to achieve filtering in noisy environments.
  • I2C interface has a timeout setting, not only to prevent bus lock but also to provide high-speed mode, to meet the communication requirements of up to 3.4 MHz.
  • All properties INA219 are software programmable to support.
  • A single power supply, the operating voltage of between +3.0 to + 5.5V.

Package Included:

1 x CJMCU219 INA219 I2C interface Bi-directional current/power monitoring sensor module


 

Reviews

There are no reviews yet.

Be the first to review “CJMCU-219 INA219 I2C Interface Power Supply Monitoring Module”

Your email address will not be published. Required fields are marked *

CJMCU-219 INA219 I2C Interface Power Supply Monitoring Module